Fujian Minshan Fire Fighting Equipment Co., Ltd. was founded in 1982.

Short Lead Time for Ul/Fm Approved Sprinkler - Water Curtain Fire Sprinkler – Minshan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Being supported by an state-of-the-art and skilled IT team, we could supply technical support on pre-sales & after-sales service for Spray/Jet Nozzle, 25 Inch Fire Hose Coupling, Fire Extinguisher Refilling, Our company quickly grew in size and reputation because of its absolute dedication to high quality manufacturing, high value of products and excellent customer service.
Short Lead Time for Ul/Fm Approved Sprinkler - Water Curtain Fire Sprinkler – Minshan Detail:

Working principle:

 

The water curtain sprinkler is a spray device fixed in the water curtain system pipe, which is used to continuously spray water to form a water curtain, protect the surface threatened by fire and form a fire separation.

Specification:

 

MODEL Nominal Diameter Thread Flow Rate K Factor Style
MS-WCS DN15 R1/2 80±4 5.6 fire sprinkler
DN20 R3/4 115±6 8.0
DN25 R1 242 16.8

 

How to use:

 

The water curtain sprinklers should be evenly arranged according to the requirements of the designed water spraying strength, and no blank spots appear, so as to prevent the flame from passing through the protected parts. The spacing of the nozzles should not be less than 2.5 m, and meet the following requirements:

(1) When the water curtain is used for protection and cooling, the sprinklers are arranged in a single row, arranged above the fire shutter, fire curtain or other protected objects, and should ensure that the water flow is evenly sprayed to the protected objects.

(2) The water curtain sprinklers at the opening of the stage opening and the hole area greater than 3 m² should be arranged in double rows inside and outside the hole, and the distance between the adjacent two rows should not be less than 1 m. The distance between each row of sprinklers should be calculated and determined based on the flow rate of the water curtain sprinklers and the designed water spray intensity.

(3) Because of the process requirements, it is not possible to set up places or parts of fire partitions (such as underground railways, underground tunnels, workshops with cranes, etc.). It is necessary to form a water curtain fire belt to replace the fire partitions. Less than 6 m. When the water curtain sprinkler is used, the nozzle arrangement should not be less than 3 rows; when the open sprinkler is used, the nozzle arrangement should not be less than 2 rows.

(4) The cornice-type water curtain sprinkler is used to protect the upper plane (such as eaves and ceiling lights), and should be set about 200 mm below the top window or cornice plate. The caliber and quantity should be selected according to the distance between the eaves beams under the eaves.

(5) The window-type water curtain nozzle is used to protect the facade or slope (walls, windows, doors, fire shutters, etc.), and should be located 50 mm below the top of the window. The distance between the faces is related to the window width. The caliber of the window type water curtain sprinkler should be selected according to the height of the floor.

(6) The number of nozzles installed in each group of water curtain system should not exceed 72.

(7) Water curtain sprinklers of the same caliber should be installed on the same water distribution branch pipe, in order to facilitate construction, maintenance management and ensure uniform water spraying of the system.

 

fire water curtain sprinkler (1) 

 

Application :

 

The slit-type water curtain sprinkler is suitable to be installed at the stage entrance to separate the stage from the audience hall, or in the area of the open-air production device, to divide the open-air production device into several small areas, or to protect some individual buildings or equipment.

Rain shower nozzles are used to protect large openings, and use fire-proof water curtain belts, such as escalators and spiral staircases in public places such as shopping malls to pass through floor openings, or large openings due to process requirements. Parts (these parts are difficult to prevent the spread and expansion of the fire with a general water curtain nozzle).

 
fire water curtain sprinkler (4) 

Production line:

 

The company has integrated a whole set of production line together, strictly comply with each part of the process requirements, control each step of the procedure, to improve the overall work efficiency.
 
fire fusible alloy sprinkler (5) 

Certificate:

 

Our company have passed the CE certification, the Certification (CCC Certificate) by CCCF, the ISO9001 and many specified standards requirements from the international market.Existing quality products are applying for UL,FM and LPCB certifications.
 
fire fusible alloy sprinkler (6) 

Exhibition:

 

Our company regularly participates in domestic and international large-scale fire exhibitions.

– China International Fire Protection Equipment Technology Conference & Exposition in Beijing.

– Canton Fair in Guangzhou.

– Interschutz in Hannover

– Securika in Moscow.

– Dubai Intersec.

– Saudi Arabia Intersec.

– Secutech vietnam in HCM.

– Secutech India in Bombay.

 
fire fusible alloy sprinkler (7) 


Product detail pictures:

Short Lead Time for Ul/Fm Approved Sprinkler - Water Curtain Fire Sprinkler – Minshan detail pictures

Short Lead Time for Ul/Fm Approved Sprinkler - Water Curtain Fire Sprinkler – Minshan detail pictures

Short Lead Time for Ul/Fm Approved Sprinkler - Water Curtain Fire Sprinkler – Minshan detail pictures


Related Product Guide:

To regularly increase the management program by virtue from the rule of "sincerely, good religion and high quality are the base of enterprise development", we greatly absorb the essence of linked products internationally, and constantly produce new goods to satisfy the calls for of shoppers for Short Lead Time for Ul/Fm Approved Sprinkler - Water Curtain Fire Sprinkler – Minshan, The product will supply to all over the world, such as: Bolivia, Manila, Ethiopia, With the development and enlargement of mass clients abroad, now we've set up cooperative relationships with many major brands. We've our own factory and also have many reliable and well-cooperated factories in the field. Adhering to the "quality first, customer first, We are provideing high-quality, low-cost items and first-class service to customers. We sincerely hope to establish business relationship with customers from all over the world on the basis of quality, mutually benefit. We welcome OEM projects and designs.
The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
5 Stars By Octavia from Philippines - 2017.09.09 10:18
Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
5 Stars By Doris from panama - 2017.06.16 18:23

Related Products