Fujian Minshan Fire Fighting Equipment Co., Ltd. was founded in 1982.
News
Factory Tour
English
Email Support
manager@minshanfire.com
Call Support
+0086 13599900200
Home
About Us
Factory Tour
Products
Fire Hose System
Fire Hose
PVC Fire Hose
Pu Fire Hose
Epdm Fire Hose
Dual Line Fire Hose
Rubber Fire Hose
Hose Coupling
Machino Coupling
NH Fire Hose Coupling
John Morris Fire Hose Coupling
Gost Fire Hose Coupling
Storz Coupling
Hose Nozzle
Jet Nozzle Complete With Branchpipe
Diffuser Nozzle 500 (Jet/Spray)
Jet/Spray Nozzle With Control Valve
Water/Foam Pistol Grip Nozzle (Jet/Fog)
Handline Nozzle Auto Water/Foam La 2″
Hose Rack Assembley
Hose Cradle
Fire Hose Reel
BS Manual Fire Hose Reel
Automatic Fire Hose Reel
European Fire Hose Reel(Swing/Fix Type)
French Fire Hose Reel
South Africa Fire Hose Reel
Wash Down Hose Reel
Cabinet With Continuous Flow Hose Reel
Continuous Flow Hose Reel
HOSE REEL Accessaries
Hose Reel Nozzle
Fire Hose (Hose Reel)
Hose Guide
Pressure Reducing Valve
Hose Reel Wall Bracket
Fire Hydrant System
Fire Hydrant Valve
Straight Through Valve
Right Angle Valve
Bib Nose Valve
Oblique Valve
Pressure Regulating Valve ‘e’ Type
Hydrant Valve International Outlet Fittings
Australian Standard Hydrant Valve As 2419.2
2-Way & 4-Way Breeching Inlet
Fire Department Connection
Collecting Breeching
Dividing Breeching
Fie Hydrant(Outdoor)
2 Way Fire Hydrant
3 Way Fire Hydrant
Underground Hydrant Bs 750
Fire Extinguisher System
Dry Powder Fire Extinguisher
Carbon Dioxide Fire Extinguisher
Foam Fire Extinguisher
Water Type Fire Extinguisher
Automatic Powder Fire Extinguisher
Cabinet For Hose Reel And Extinguisher
Hose Reel Cabinet
Hose Reel Cabinet
Double Compartment Hose Reel Cabinet
2 Way And 4 Way Breeching Inlet Cabinet
Hose Cabinet
Abcd Type
Fire Extinguisher Cabinet
News
Contact Us
Home
Featured
Featured
OEM Customized Swing Check Valve - PU Fire Hose – Minshan
Technical Specifications Item: Lined Fire Hose Fire Hose Type: Single Jacket Hose Tube Material: PVC Nitrile Hose Cover Material: Rubber Quality Standard: EN14540,BS6391 Hose & Coupling Sizes Size Large Diameter High water flow Hydrant Ready Easy Handing Pump Ready 1’’ √ √ √ √ √ 1.5’’ √ √ √ √ √ 2’’ √ √ √ √ √ 2.5’’ √ √ √ √ √ 3’’ √ √ √ √ √ 4’’ √ √ √ √ √ Features: Working Pres...
inquiry
detail
Factory directly supply Stainless Steel Fire Hose Cabinet With Hook - STORZ Fire Hose Coupling – Minshan
Features: –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃ Different Type Hose Couplings DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Wor...
inquiry
detail
8 Year Exporter Standard Type Sprinkler - Percussive type water curtain sprinkler – Minshan
Working principle: During a fire, the sprinkler continuously sprays water mist on the exposed heat absorbing surfaces of various buildings near the fire area to prevent the heat absorption of the exposed surfaces and the spread of fire to protect the safety of various buildings. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style MS-WCS DN15 R1/2 80±4 5.6 fire sprinkler DN20 R3/4 115±6 8.0 DN25 R1 242 16.8 How to use: The water spray nozzle used in the...
inquiry
detail
Factory source Fire Protection - Fire Angle Hose Valve – Minshan
Working principle: The Flange Landing Valve is supplied by the indoor pipe network to the fire site with a valve interface. It is a fixed fire-fighting facility for factories, warehouses, high-rise buildings, public buildings and ships. It is usually installed in the fire hydrant box and is connected to the fire hose and water nozzle Supporting the use of. Specification: MODEL Nominal Diameter Thread Nominal Pressure Style MS-FLV DN40 1 1/2 PN16 Flange Landing Valve DN50 2 PN16 ...
inquiry
detail
Good quality UL Fm Approved - White color Water Hose fire hose PVC rubber fire hose – Minshan
Specifications Tube and cover: PVC Reinforcement: 100% virgin high tenacity polyester Jacket Technical Characteristics: _ excellent abrasion-resistance _ heat resistant _ seawater and weather resistant _ resistant to oil and petrol _ resistant to alkalies, acids, liquids, chemicals _ ageing, ozone and UV rays resistant _ excellent adhesion between rubber and jacket _ temperature range from -30°C up to +80°C _ maintenance free _ cleaning and drying not necessary Features: Working Press...
inquiry
detail
Rapid Delivery for Stainless Steel Hose Joint - Upright Fire Sprinkler – Minshan
Working principle: The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTZ DN15 R1/2 80±4 5.6 Upright fire sprinkler DN20 R3/4 115±6 8.0 How to use: 1. The installation distance of the spray head is generally...
inquiry
detail
OEM Customized Swing Check Valve - JOHN MORRIES Fire Hose Coupling – Minshan
Features: –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃ Different Type Hose Couplings DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Working P...
inquiry
detail
18 Years Factory Antique Brass Fire Hose Nozzles - STORZ Fire Hose Coupling – Minshan
Features: –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃ Different Type Hose Couplings DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Wor...
inquiry
detail
Manufacturer for Sprayers - Upright Fire Sprinkler – Minshan
Working principle: The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTZ DN15 R1/2 80±4 5.6 Upright fire sprinkler DN20 R3/4 115±6 8.0 How to use: 1. The installation distance of the spray head is generally...
inquiry
detail
Ordinary Discount Outdoor Fire Hose Cabinet - NST Fire Hose Coupling – Minshan
Features: –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃ Different Type Hose Couplings DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Worki...
inquiry
detail
Discount Price Fire Hose Cabinets Manufacturers - Fire Flange Landing Valve – Minshan
Working principle: The Flange Landing Valve is supplied by the indoor pipe network to the fire site with a valve interface. It is a fixed fire-fighting facility for factories, warehouses, high-rise buildings, public buildings and ships. It is usually installed in the fire hydrant box and is connected to the fire hose and water nozzle Supporting the use of. Specification: MODEL Nominal Diameter Thread Nominal Pressure Style MS-FLV DN40 1 1/2 PN16 Flange Landing Valve DN50 2 PN16 ...
inquiry
detail
OEM manufacturer Water Flow Sprinkler - Sidewall Fire Sprinkler – Minshan
Working principle: The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTBS DN15 R1/2 80±4 5.6 Horizontal sidewall fire sprinkler DN20 R3/4 115±6 8.0 How to use: 1. The installation distance of the spray he...
inquiry
detail
<<
< Previous
393
394
395
396
397
398
399
Next >
>>
Page 396 / 477