Fujian Minshan Fire Fighting Equipment Co., Ltd. was founded in 1982.

Featured

  • Super Lowest Price Cast Brass Valve - FIRE NOZZLE – Minshan

    Super Lowest Price Cast Brass Valve - FIRE NOZZLE – Minshan

    Working principle:   It is a water jetting tool for fire extinguishing. When it is connected with the hose, it will spray dense and full water flow, which has the advantages of long range and large water volume.   Specification:   MODEL Style Size MS-BN fire nozzle 1 1/2’’ 2’’ 2 1/2’’   How to use:   1.Pull open the fire hydrant door, take out the hose and water gun. 2.Check whether the hose and connector are in good condition. If it is damaged, it is forbidden to use...
  • OEM/ODM Factory Fire Hose Reel Specification - Fire Angle Hose Valve – Minshan

    OEM/ODM Factory Fire Hose Reel Specification - Fire Angle Hose Valve – Minshan

    Working principle:   The Flange Landing Valve is supplied by the indoor pipe network to the fire site with a valve interface. It is a fixed fire-fighting facility for factories, warehouses, high-rise buildings, public buildings and ships. It is usually installed in the fire hydrant box and is connected to the fire hose and water nozzle Supporting the use of.   Specification:   MODEL Nominal Diameter Thread Nominal Pressure Style MS-FLV DN40 1 1/2 PN16 Flange Landing Valve DN50 2 PN16 ...
  • 100% Original Micro Spray Tape - Percussive type water curtain sprinkler – Minshan

    100% Original Micro Spray Tape - Percussive type water curtain sprinkler – Minshan

    Working principle:   During a fire, the sprinkler continuously sprays water mist on the exposed heat absorbing surfaces of various buildings near the fire area to prevent the heat absorption of the exposed surfaces and the spread of fire to protect the safety of various buildings.   Specification:   MODEL Nominal Diameter Thread Flow Rate K Factor Style MS-WCS DN15 R1/2 80±4 5.6 fire sprinkler DN20 R3/4 115±6 8.0 DN25 R1 242 16.8   How to use:   The water spray nozzle used in the...
  • Factory Supply Pvc Spray Nozzle - Pendent Fire Sprinkler – Minshan

    Factory Supply Pvc Spray Nozzle - Pendent Fire Sprinkler – Minshan

    Working principle:   The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water.   Specification:   MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTX DN15 R1/2 80±4 5.6 Pendent fire sprinkler DN20 R3/4 115±6 8.0   How to use:   1. The installation distance of the spray head is general...
  • Cheap PriceList for Right Angel Valve - JOHN MORRIES Fire Hose Coupling – Minshan

    Cheap PriceList for Right Angel Valve - JOHN MORRIES Fire Hose Coupling – Minshan

    Features:   –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃ Different Type Hose Couplings       DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Working P...
  • OEM/ODM Manufacturer Spray Nozzle - Fire HydrantLanding Valve – Minshan

    OEM/ODM Manufacturer Spray Nozzle - Fire HydrantLanding Valve – Minshan

    Working principle:   The Fire HydrantLanding Valve supplied by the indoor pipe network to the fire site with a valve interface. It is a fixed fire-fighting facility for factories, warehouses, high-rise buildings, public buildings and ships. It is usually installed in the fire hydrant box and is connected to the fire hose and water nozzle Supporting the use of.   Specification:   MODEL Nominal Diameter Thread Nominal Pressure Style MS-FLV DN40 1 1/2 PN16 Flange Landing Valve DN50 2 PN1...
  • Excellent quality Ss 316 Material Nozzles - Water Curtain Fire Sprinkler – Minshan

    Excellent quality Ss 316 Material Nozzles - Water Curtain Fire Sprinkler – Minshan

    Working principle:   The water curtain sprinkler is a spray device fixed in the water curtain system pipe, which is used to continuously spray water to form a water curtain, protect the surface threatened by fire and form a fire separation. Specification:   MODEL Nominal Diameter Thread Flow Rate K Factor Style MS-WCS DN15 R1/2 80±4 5.6 fire sprinkler DN20 R3/4 115±6 8.0 DN25 R1 242 16.8   How to use:   The water curtain sprinklers should be evenly arranged according to the requ...
  • Professional China Brass Fire Hydrant Valve - STORZ Fire Hose Coupling – Minshan

    Professional China Brass Fire Hydrant Valve - STORZ Fire Hose Coupling – Minshan

    Features:   –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃   Different Type Hose Couplings         DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Wor...
  • China New Product Alarm Check Valve Price - Foam Fire Sprinkler – Minshan

    China New Product Alarm Check Valve Price - Foam Fire Sprinkler – Minshan

    Working principle:   Foam water sprinkler is a special fire-extinguishing component that produces and sprays empty foam. It is mainly used in low-expansion foam sprinkler systems. The foam mixture is transported to the foam sprinkler through the pipe. Protect the danger zone to achieve the purpose of extinguishing the fire. Specification:   MODEL Nominal Diameter Thread Flow Rate K Factor Style MS-FS DN15 R1/2 80±4 5.6 Foam fire sprinkler DN20 R3/4 115±6 8.0   How to use:   1.PT s...
  • Hot New Products Hose Brass Nozzle - Percussive type water curtain sprinkler – Minshan

    Hot New Products Hose Brass Nozzle - Percussive type water curtain sprinkler – Minshan

    Working principle:   During a fire, the sprinkler continuously sprays water mist on the exposed heat absorbing surfaces of various buildings near the fire area to prevent the heat absorption of the exposed surfaces and the spread of fire to protect the safety of various buildings.   Specification:   MODEL Nominal Diameter Thread Flow Rate K Factor Style MS-WCS DN15 R1/2 80±4 5.6 fire sprinkler DN20 R3/4 115±6 8.0 DN25 R1 242 16.8   How to use:   The water spray nozzle used in the...
  • Factory selling Nozzles Tips - Upright Fire Sprinkler – Minshan

    Factory selling Nozzles Tips - Upright Fire Sprinkler – Minshan

    Working principle:   The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification:   MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTZ DN15 R1/2 80±4 5.6 Upright fire sprinkler DN20 R3/4 115±6 8.0 How to use:   1. The installation distance of the spray head is generally...
  • Renewable Design for Flange Fire Hydrant - Fire Flange Landing Valve – Minshan

    Renewable Design for Flange Fire Hydrant - Fire Flange Landing Valve – Minshan

    Working principle:   The Flange Landing Valve is supplied by the indoor pipe network to the fire site with a valve interface. It is a fixed fire-fighting facility for factories, warehouses, high-rise buildings, public buildings and ships. It is usually installed in the fire hydrant box and is connected to the fire hose and water nozzle Supporting the use of.   Specification:   MODEL Nominal Diameter Thread Nominal Pressure Style MS-FLV DN40 1 1/2 PN16 Flange Landing Valve DN50 2 PN16 ...