Fujian Minshan Fire Fighting Equipment Co., Ltd. was founded in 1982.
News
Factory Tour
English
Email Support
manager@minshanfire.com
Call Support
+0086 13599900200
Home
About Us
Factory Tour
Products
Fire Hose System
Fire Hose
PVC Fire Hose
Pu Fire Hose
Epdm Fire Hose
Dual Line Fire Hose
Rubber Fire Hose
Hose Coupling
Machino Coupling
NH Fire Hose Coupling
John Morris Fire Hose Coupling
Gost Fire Hose Coupling
Storz Coupling
Hose Nozzle
Jet Nozzle Complete With Branchpipe
Diffuser Nozzle 500 (Jet/Spray)
Jet/Spray Nozzle With Control Valve
Water/Foam Pistol Grip Nozzle (Jet/Fog)
Handline Nozzle Auto Water/Foam La 2″
Hose Rack Assembley
Hose Cradle
Fire Hose Reel
BS Manual Fire Hose Reel
Automatic Fire Hose Reel
European Fire Hose Reel(Swing/Fix Type)
French Fire Hose Reel
South Africa Fire Hose Reel
Wash Down Hose Reel
Cabinet With Continuous Flow Hose Reel
Continuous Flow Hose Reel
HOSE REEL Accessaries
Hose Reel Nozzle
Fire Hose (Hose Reel)
Hose Guide
Pressure Reducing Valve
Hose Reel Wall Bracket
Fire Hydrant System
Fire Hydrant Valve
Straight Through Valve
Right Angle Valve
Bib Nose Valve
Oblique Valve
Pressure Regulating Valve ‘e’ Type
Hydrant Valve International Outlet Fittings
Australian Standard Hydrant Valve As 2419.2
2-Way & 4-Way Breeching Inlet
Fire Department Connection
Collecting Breeching
Dividing Breeching
Fie Hydrant(Outdoor)
2 Way Fire Hydrant
3 Way Fire Hydrant
Underground Hydrant Bs 750
Fire Extinguisher System
Dry Powder Fire Extinguisher
Carbon Dioxide Fire Extinguisher
Foam Fire Extinguisher
Water Type Fire Extinguisher
Automatic Powder Fire Extinguisher
Cabinet For Hose Reel And Extinguisher
Hose Reel Cabinet
Hose Reel Cabinet
Double Compartment Hose Reel Cabinet
2 Way And 4 Way Breeching Inlet Cabinet
Hose Cabinet
Abcd Type
Fire Extinguisher Cabinet
News
Contact Us
Home
Featured
Featured
Low price for Water Mist System - Concealed Fire Sprinkler – Minshan
Working principle: 1. Concealed fire sprinkler head, the main medium is water, in order to protect the performance of the sprinkler head, the inlet of the sprinkler head can be equipped with a filter. 2. Concealed firefighting sprinklers, if the firefighting sprinklers extinguish liquid fires, water foam can be added to the water to improve the fire extinguishing effect. 3. Concealed fire sprinklers, fire sprinklers should be inspected at least quarterly after installation, and the dirt o...
inquiry
detail
Short Lead Time for Factory Fire Hose - DUAL LINE Fire Hose – Minshan
Double Jacket Fire Hose Advantage 1.There are many types made for firefighting per different standards. 2.It attaches to pumps, fire hoses, hydrants, PVC pipes that are equipped with various fittings. Alternatively, it can be adapted to fit any of the above mentioned with simple pipe or hose adapters. 3.The strongest woven hose you can find, with DUAL layers of polyester hose. It’s just like having two hoses combined into one. Hose & Coupling Sizes Size Large Diamet...
inquiry
detail
China wholesale Recessed Type Fire Hose Cabinet Fire Rated Cabinet - Fire HydrantLanding Valve – Minshan
Working principle: The Fire HydrantLanding Valve supplied by the indoor pipe network to the fire site with a valve interface. It is a fixed fire-fighting facility for factories, warehouses, high-rise buildings, public buildings and ships. It is usually installed in the fire hydrant box and is connected to the fire hose and water nozzle Supporting the use of. Specification: MODEL Nominal Diameter Thread Nominal Pressure Style MS-FLV DN40 1 1/2 PN16 Flange Landing Valve DN50 2 PN1...
inquiry
detail
Chinese Professional Fire Sprinkler - Upright Fire Sprinkler – Minshan
Working principle: The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTZ DN15 R1/2 80±4 5.6 Upright fire sprinkler DN20 R3/4 115±6 8.0 How to use: 1. The installation distance of the spray head is generally...
inquiry
detail
China Supplier 65mm Rubber Fire Hose - PU Fire Hose – Minshan
Technical Specifications Item: Lined Fire Hose Fire Hose Type: Single Jacket Hose Tube Material: PVC Nitrile Hose Cover Material: Rubber Quality Standard: EN14540,BS6391 Hose & Coupling Sizes Size Large Diameter High water flow Hydrant Ready Easy Handing Pump Ready 1’’ √ √ √ √ √ 1.5’’ √ √ √ √ √ 2’’ √ √ √ √ √ 2.5’’ √ √ √ √ √ 3’’ √ √ √ √ √ 4’’ √ √ √ √ √ Features: Working Pres...
inquiry
detail
2018 Latest Design Silent Check Valve - High Quality Low Price PVC Fire Fighting Hose – Minshan
Specifications Tube and cover: PVC Reinforcement: 100% virgin high tenacity polyester Jacket Technical Characteristics: _ excellent abrasion-resistance _ heat resistant _ seawater and weather resistant _ resistant to oil and petrol _ resistant to alkalies, acids, liquids, chemicals _ ageing, ozone and UV rays resistant _ excellent adhesion between rubber and jacket _ temperature range from -30°C up to +80°C _ maintenance free _ cleaning and drying not necessary Fe...
inquiry
detail
Low price for Zstw Type Water Curtain Nozzle - Pendent Fire Sprinkler – Minshan
Working principle: The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTX DN15 R1/2 80±4 5.6 Pendent fire sprinkler DN20 R3/4 115±6 8.0 How to use: 1. The installation distance of the spray head is general...
inquiry
detail
High Quality Brass John Morris Coupling Use For Fire Hose - FIRE NOZZLE – Minshan
Working principle: It is a water jetting tool for fire extinguishing. When it is connected with the hose, it will spray dense and full water flow, which has the advantages of long range and large water volume. Specification: MODEL Style Size MS-BN fire nozzle 1 1/2’’ 2’’ 2 1/2’’ How to use: 1.Pull open the fire hydrant door, take out the hose and water gun. 2.Check whether the hose and connector are in good condition. If it is damaged, it is forbidden to use...
inquiry
detail
Cheap price Fire Hose Cabinet Glass - PVC Fire Hose – Minshan
Specifications Tube and cover: PVC Reinforcement: 100% virgin high tenacity polyester Jacket Technical Characteristics: _ excellent abrasion-resistance _ heat resistant _ seawater and weather resistant _ resistant to oil and petrol _ resistant to alkalies, acids, liquids, chemicals _ ageing, ozone and UV rays resistant _ excellent adhesion between rubber and jacket _ temperature range from -30°C up to +80°C _ maintenance free _ cleaning and drying not necessary Features: ...
inquiry
detail
Factory Cheap Esfr Fire Sprinkleresfr - Pendent Fire Sprinkler – Minshan
Working principle: The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTX DN15 R1/2 80±4 5.6 Pendent fire sprinkler DN20 R3/4 115±6 8.0 How to use: 1. The installation distance of the spray head is general...
inquiry
detail
Europe style for Fire Sprinkler Parts - Upright Fire Sprinkler – Minshan
Working principle: The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTZ DN15 R1/2 80±4 5.6 Upright fire sprinkler DN20 R3/4 115±6 8.0 How to use: 1. The installation distance of the spray head is generally...
inquiry
detail
100% Original Fire Hose Angle Valve - Fire Angle Hose Valve – Minshan
Working principle: The Flange Landing Valve is supplied by the indoor pipe network to the fire site with a valve interface. It is a fixed fire-fighting facility for factories, warehouses, high-rise buildings, public buildings and ships. It is usually installed in the fire hydrant box and is connected to the fire hose and water nozzle Supporting the use of. Specification: MODEL Nominal Diameter Thread Nominal Pressure Style MS-FLV DN40 1 1/2 PN16 Flange Landing Valve DN50 2 PN16 ...
inquiry
detail
<<
< Previous
343
344
345
346
347
348
349
Next >
>>
Page 346 / 477